    ● 0–60V DC voltage, 0–3A current output, maximum 180W power, meeting the diverse power supply needs of laboratory and industrial scenarios. ● Built-in overcurrent and overvoltage protection functions, which respond quickly in abnormal situations. ● Supports automatic switching between constant voltage / constant current modes without manual intervention, adapting to different load characteristics. ● Load regulation rate ≤5mA, linear regulation rate 3×10⁻¹+3mA, meeting application scenarios with strict requirements on current accuracy.
    *
    🚚 Free shipping
    ā±ļø Delivery: 6-12 days
    šŸ”™ 30-day Returns
    Overview

    Economically priced 0 to 60V, 0 to 3A linear regulated DC power supply for industrial and lab use, with selectable 110V/220V±10% AC input, 3-digit LED display, 180W output, and automatic CV/CC mode switching. This precision power solution delivers stable, low-noise variable voltage/current, supports both digital and analog control for seamless system integration, and offers exceptional value for R&D, manufacturing, and quality assurance applications—backed by reliable performance to boost your operational efficiency and project success.

    Linear Adjustable DC Power Supply Features

    Feature

    • Dual-channel Output Design: Engineered with a dual-output architecture, it can power two separate device groups simultaneously.
    • Energy-saving Efficiency: Boasting a conversion efficiency of over 65%, this power supply delivers a stable output while minimizing energy consumption and heat generation.
    • Global Voltage Compatibility: Supporting both 110V and 220V AC input, this unit ensures stable and reliable operation across diverse power grid environments worldwide, making it ideal for international deployment.
     

    Details

    1. Intuitive Mode Indication: Clear CV/CC status lights provide instant, at-a-glance insight into the current operating mode.
    2. High-precision Digital Display: A bright 3-digit digital screen delivers real-time voltage readouts with up to 100mV resolution, meeting the demands of precision testing and experimentation.
    3. Dual-knob Control System: Coarse and fine adjustment knobs enable both rapid large-range parameter changes and precise target-value tuning, optimizing both operational speed and accuracy.
    60V 3A Linear Adjustable DC Power Supply Detail

    60V 3A Linear DC Power Supply Structure

    60V 3A Linear Adjustable DC Power Supply Structure

    Specs
    Model PH-JK603S
    Input Voltage 110V or 220V AC (+/- 10%)
    Output Voltage Range DC 0-60V
    Output Current Range 0-3A
    Output Power 180W
    Frequency 50Hz/60Hz
    Output Type Dual
    Display 3 digit
    Display Accuracy ≤ ±0.4%+3d
    Voltage Display Resolution 10mV
    Current Display Resolution 10mA
    Efficiency >65%
    Voltage Regulation
    Load Regulation (CV) 1Ɨ10-1+8mV
    Line Regulation (CV) 1Ɨ10-1+3mV
    Ripple & Noise (P-P) 0.5mV
    Temperature Coefficient 300PPļ½/ā„ƒ
    Current Regulation
    Load Regulation (CC) ≤5mA
    Line Regulation (CC) 3Ɨ10-1+3mA
    Temperature Coefficient 500PPļ½/ā„ƒ
    Others
    Protection Over Load and Over Voltage Protection
    Recovery Time ≤100µs
    Operating Ambient -10ā„ƒ to + 40ā„ƒ/ 85%RH
    Storage Ambient -10ā„ƒ to + 80ā„ƒ/ 80%RH
    Warranty 12 Months
    Size 290 (L) x 130 (W) x 165 (H) mm
    Weight 5.5kg
    Application
    Bioelectric Signal Acquisition Device

    Bioelectric Signal Acquisition Device

    Communication Module

    Communication Module

    Automotive Electronics Testing

    Automotive Electronics Testing

    Experimental Electronic Instruments

    Experimental Electronic Instruments

    FAQ

    Q1: What precautions should I take when using linear regulated DC power supply?

    When using a linear regulated DC power supply, always prioritize safety and proper operation: Verify your device’s voltage and current ratings match the supply specs, set appropriate limits before connecting, use insulated tools and avoid exposed metal parts, secure loads and double-check polarities, gradually adjust voltage/current while monitoring for irregularities, prevent short circuits and high-current overheating, turn off the unit before adjustments or load changes, inspect cables and connections for wear, and follow manufacturer guidelines and your model’s user manual for specific precautions.

    Q2: What should I do when overcurrent or overvoltage protection is triggered?

    If your linear DC power supply triggers overcurrent or overvoltage protection, first disconnect the load and turn off the unit to reset it; check for short circuits, incorrect polarity, or overloaded conditions, verify your device’s voltage and current requirements match the supply settings, then gradually reapply power while monitoring for irregularities, and consult the user manual or manufacturer if issues persist.

    0.0 0
    Write your own review Close
    *
    *