Rated Power |
1kW |
Peak Power (20ms) |
3000VA |
Support Starter Motor |
1Hp |
DC Input Voltage |
12VDC/24VDC (optional) |
DC Input Voltage Ranges |
10.5-15VDC |
Utility Input Voltage |
110VAC / 120VAC / 220VAC / 230VAC / 240VAC (same as the output voltage) |
Utility Input Frequency |
50Hz / 60Hz (adjustable) |
PV Charge Control Current |
30A/60A (optional) |
Maximum Mains Charging Current |
0~30A (depending on model) |
Mains Charging Method |
Three-stage (constant current, constant voltage, float) |
Inverter Output Efficiency |
ā„85% |
Inverter Output Voltage |
ACĀ±2%: 110V/120/ 220/230V/240V (optional) |
Inverter Output Frequency |
50/60HzĀ±1% |
Inverter Output Waveform |
Pure sine wave |
Utility Output Efficiency |
>99% |
Utility Output Voltage Range |
110VACĀ±10% / 120VACĀ±10% / 220VACĀ±10% / 230VACĀ±10% / 240VACĀ±10% |
Utility Output Frequency Range |
Auto-tracking |
Inverter Output Waveform Distortion |
ā¤3% (linear load) |
Battery Mode No-load loss |
ā¤0.8% of rated power |
No-load Loss in Utility Mode |
ā¤ 2% of rated power (mains charger not working) |
Energy Saving Mode No-load Loss |
ā¤10W |
Valve Regulated Lead Acid Batteries |
Average charging voltage:14.2V; Floating charging voltage:13.8V(12V system; 24V system*2; 48V system*4) |
Customized Batteries |
Customized charging and discharging parameters for different types of batteries (charging and discharging parameters for different types of batteries can be set through the operation panel) |
Battery Undervoltage Alarm |
11V |
Battery Undervoltage Protection |
10.5V |
Battery Over-voltage Alarm |
15V |
Battery Overvoltage protection |
17V |
Battery Overvoltage Recovery Voltage |
14.5V |
Overload Power Protection |
Automatic protection (battery mode), circuit breaker or fuse (mains mode) |
Inverter Output Short Circuit Protection |
Automatic protection (battery mode), circuit breaker or fuse (mains mode) |
Temperature Protection |
>90Ā°C (output off) |
Alarm A |
Normal working condition, no alarm sound from buzzer |
Alarm B |
Buzzer beeps 4 times per second in case of battery failure, abnormal voltage, overload protection |
Alarm C |
When the machine is turned on for the first time and the machine is normal, the buzzer will beep 5 times |
Operating Mode |
Inverter priority/utility priority/energy saving mode |
Conversion Time |
ā¤4ms |
Panel Display |
LCD |
Heat Dissipation Method |
Smart fan control |
Communication Function (optional) |
Mobile APP (WIFI monitoring or GPRS monitoring) |
Operating Temperature |
-10ā~40ā |
Storage Temperature |
-15ā~60ā |
Noise |
ā¤55dB |
Altitude |
2,000 m (exceeding the amount to be used at a reduced rate) |
Relative Humidity |
0%~95%, no condensation |
Machine Size |
555*294*184 (mm) |