    1200VA UPS Backup Power Supply, Single Phase 12V/240V

    SKU: PH-UPS-1.2K
    $732.15
    ● UPS with capacity 1200VA/700W, 120V/220V AC input and output selectable. ● Built-in lead-acid battery, synchronized sine wave output. ● Provides emergency power during power outages, reducing harmonic distortion. ● Suitable for emergency power backup in network equipment, office systems, switches, monitoring systems, etc.
    *
    đźšš Free shipping
    ⏱️ Delivery: 6-12 days
    đź”™ 30-day Returns
    Overview

    This 1200VA/700W uninterruptible power supply supports 220V/120V AC input, outputs corrected sine wave power, and features a built-in high-performance lead-acid battery. With a conversion time 6-8ms, it responds quickly to sudden power outages, providing stable power support to the load. Suitable for home offices, small business systems, and communication equipment, maintaining stable output even under power grid fluctuations or abnormal power conditions, effectively preventing data loss, system crashes, and equipment damage.

    Feature

    Feature

    • The 1200VA UPS provides basic backup power with multiple power protection features.
    • Complete power switching within 6-8ms and includes overload protection, short-circuit protection, and over-temperature protection.
    • Reduces harmonic distortion and electronic interference, improving equipment operational safety.
    • Suitable for applications such as computer systems, network equipment, security monitoring systems, and small servers, providing reliable power protection for critical equipment.
     

    Details

    1. RS232 communication port
    2. DC input
    3. Fuse
    4. Cooling fan
    5. AC output
    6. AC input
    Details
    Specs
    Model BE-1200
    Rated Capacity 1200VA/700W
    Phase Single Phase (L, N, G) * NOT support the split phase (L1, L2 + G) like USA standard.
    UPS Type Line Interactive
    Weight 10kg
    Size 380*140*215mm
    Input
    Input Voltage Range 172-275V AC/ 85-135V AC
    Nominal Input Voltage 220V/230V/240V/110V/120V AC
    Input Frequency 45-65Hz
    Output
    Norminal Output Voltage 220V/120V AC
    Output Voltage Range (Normal Mode) 220V/120V AC±10%
    Output Voltage Range (Battery Mode) 220V/120V AC±10% (Modified Sine Wave)
    Output Frequency (Normal Mode) Synchronized (Sine Wave)
    Output Frequency (Battery Mode) 50/60Hz±0.2%
    Wave Form Modified Sine Wave
    Power Factor 0.9
    Output Socket Universal socket
    Efficiency >90%
    Transfer Time 6-8ms
    Batteries & Runtime
    Battery Type Maintenance-free lead-acid battery
    Battery Modules (NOT Included) 12V*7Ah*2pcs/24V
    (Battery size: 150*90*60mm)
    Backup Time (full/half load) 5 Minutes Backup time; for long backup mode, it depends on outside battery
    Typical Charge Time <12 hours (90%)
    Display Status LCD (NORMAL, FAULT, BATTERY, CHARGE, OVERLOAD)
    Protection
    Overload Protection Automatic shut down when overload is within 110~130%
    Shut down after 300ms when above 130%
    Others
    Peak Ratio for Load 3:1 (Max.)
    Distortion Rate (full load) Linear Load <3%
    Distortion Rate (full load) Non-linear Load <6%
    Communication Software NETCCA POWER
    Operating Environment
    Working Temperature 0°C~40°C
    Relative Humidity 20~90% Non-condensing
    Application
    Office equipment

    Office Equipment

    Computer network

    Computer Network

    Intelligent home

    Intelligent Home

    Lighting system

    Lighting System

    FAQ

    Q1: What power types does a uninterruptible power supply support?

    UPS backup systems typically support both single-phase and three-phase power. Single-phase UPSs are commonly used in homes, small offices, computer equipment, and network equipment; three-phase UPSs are frequently used in data centers, industrial production lines, and large medical equipment—high-power applications. Furthermore, depending on the power supply method, industrial ups systems can be categorized as standby, line-interactive, and online, each suitable for different load levels and power quality requirements.

    Q2: Does a ups uninterrupted power supply need to be always on?

    Generally, it is recommended to keep the ups power supply always on and continuously connected to mains power. This ensures the battery is fully charged and in good condition, providing immediate power in case of a power outage. Prolonged disconnection or inactivity without charging can cause battery deterioration due to self-discharge, affecting battery life. However, if the back up power supply is not used for an extended period (e.g., several months), it is recommended to periodically power it on for maintenance and charging to extend battery life.

    Q3: What devices are suitable for a modified sine wave backup power supply?

    Modified sine wave UPS (analog wave UPS) is suitable for devices with lower power consumption and less stringent power waveform requirements, such as desktop computers, monitors, routers, switches, optical modems, surveillance equipment, and some office equipment. These devices typically use switching power adapters and have high waveform tolerance. However, for high-end devices with motors, precision instruments, or active PFC power supplies, a pure sine wave ups power backup is recommended for better compatibility and stability.